ECP-01-NGI

ECP-01-NGI electrochemical protection local terminal station is designed for collection, logging and storage of corrosion protection parameter values, electrochemical protection (ECP) equipment operation optimization through ECP station operation mode adjustment, ECP means standby time and quantity tracking and event log generation.

Подробнее…

UKM-LKS-NGI

UKM-LKS-NGI corrosion monitoring devices are designed for electrochemical protection (ECP) complex support and corrosion parameters monitoring   of underground steel installation located within the compressor station limited territory.

Подробнее…

UKM-L-NGI

UKM-L-NGI corrosion monitoring devices are designed for electrochemical corrosion protection (ECP) of underground steel installations, including those located in the soil with increased aggressivity, equipped with remote control, parameters adjustment and  IPE-NGI cathode protection device automatic reservation systems.

Подробнее…

IPE-2,4-NGI

IPE-NGI devices are designed for corrosion protection of underground steel installations, including those located in the soil with increased aggressivity, and for use as part of UKM-L-NGI type corrosion monitoring systems with remote control and electrochemical protection (ECP) parameters adjustment.

Подробнее…

IPE-1,2/25-NGI

IPE-NGI devices are designed for corrosion protection of underground steel installations, including those located in the soil with increased aggressivity, and for use as part of UKM-L-NGI type corrosion monitoring systems with remote control and electrochemical protection (ECP) parameters adjustment.

Подробнее…

IPE-0,6-NGI

IPE-NGI devices are designed for corrosion protection of underground steel installations, including those located in the soil with increased aggressivity, and for use as part of UKM-L-NGI type corrosion monitoring systems with remote control and electrochemical protection (ECP) parameters adjustment.

Подробнее…

BI-NGI

The BI-NGI measurement transducer is a component part of KIP-L-NGI and KIP-L-04-NGI type test station and is intended for measurement of voltage, direct current amperage and electric impedance for determination of installation electrochemical protection (ECP) parameters.

Подробнее…

KIP-NGI

Test stations KIP-NGI are designed for electrochemical protection (ECP) parameters control, ECP system elements switchover and pipeline routes identification in compliance with GOST 51164-98. The test stations comply with GAZPROM, OJSC’s Interim Technical Specifications for Pipeline ECP Control and Measuring Devices.

Подробнее…

AVR-01-NGI

Emergency Load Transfer Unit AVR-01-NGI is designed for two cathode protection devices (CPD) “cold” standby arrangement, transfer of active CPD output current to the load, and protection of CPD from voltage drops and boosts in the 230 V AC power supply.

Подробнее…